Project Description
Solenoid valve ZEW
- 2/2 NC
- indirect acting
- piston-type valve
- for proper operation require differential pressure (ΔPMIN= 0,8 bar)
- applied in installations in which the water (liquid) flow is two-positions controlled, eg:
- – industrial and home water installations
– irrigation systems
– dosing and sanitary devices in the food industry, breweries, slaughterhouses
– automated public baths
Fluid media | Water, water solutions, non-aggressive liquids |
Pressure | See tab „Dimensions / Pressures” |
Fluid media temperature | max. +80°C |
Ambient temperature | -10°C ÷ +60°C |
Voltage | AC(50Hz) 12V, 24V, 110V, 230V; DC 12V, 24V |
Power | AC 26VA, DC 26W |
Closing time | < 1s |
Operation type | Continuous (100%) |
Degree of protection | IP54 |
Valve body material | Brass |
Sealing material | ethylene propylene diene methylene rubber EPDM |
Mounting position | coil upwards -acceptable deviation from vertical position up to 90O |
Typ | Dn | Rp | A [mm] |
B [mm] |
E* [mm] |
L [mm] |
PMAX [bar] |
ΔP [bar] |
Kv** [m³/h] |
M [kg] |
---|---|---|---|---|---|---|---|---|---|---|
Threaded connection: | ||||||||||
ZEW-20 | 20 | 3/4 | 128 | 18 | 54/37** | 75 | 8 | 0,8/8 | 1,50 | 0,9 |
ZEW-25 | 25 | 1 | 138 | 19 | 54/50** | 90 | 8 | 0,8/8 | 3,00 | 1,3 |
ZEW-40 | 40 | 1 1/2 | 162 | 33 | 68 | 120 | 8 | 0,8/8 | 5,00 | 2,1 |
ZEW-50 | 50 | 2 | 178 | 40 | 82 | 150 | 8 | 0,8/8 | 9,40 | 3,1 |
* – maxiumum width of valve
** – valve width without coil
- valves utilize process pressure for operation
- valves operate correctly only if there is a minimum differential pressure ΔPmin on the valve. In case it is smaller than required, valves of this type will not work properly.
- differential pressure ΔP is needed to open the valve and keep it open,
- the time of opening and closing the valve depends on the size of this difference
- due to the small cross-sections of the control channels, they are sensitive to contamination (appropriate filters should be used upstream of them)
- long actuation time (in some types even up to several seconds)
- lower lifespan (on average – several hundred of thousand work cycles)